0

newspaper-1-filled

SPD-3.1M

Product description

The detector is designed to detect fires in enclosed spaces of various buildings and structures, accompanied by the appearance of smoke, and transmit the “FIRE” signal to the control panel of the “Signal”, “VERS”, “PPK-2M” type.

    • 2-wire connection to the control panel
    • High resistance to false starts
    • Indication of duty mode and "Fire" mode
    • Compatibility with various PPKP
    • The possibility of installation both on the ceiling and on the wall
    • Availability of decorative rings for installation on suspended ceilings
    • Wide range of supply voltage
    • The possibility of connecting ZPOS

Specifications

Characteristic

Value

Supply voltage:

10 - 30 V

Current consumption in standby mode:

0.095 mA

The method of connecting to the PPK:

two-wire AL

Dimensions:

no more than 100х48 mm

Obvious indication of the worm mode:

Yes

Maximum permissible current in FIRE mode:

(УКР) 30 мA

Power off time to return to normal operation mode:

3 sec

The method of forming the output signal:

contactless

Useful materials


Warning: Trying to access array offset on false in /home/kuzenkos/arton.com.ua/new/wp-content/themes/arton/woocommerce/content-single-product.php on line 357
Name Country Comment Open Download
Manual       english
Сertificate EU(European Union) certificate_cpr-0077.pdf
DOP EU(European Union)
Scheme       Packed file of connection schemes
Packed    

Devices with which it is used

 > uncategorized - discontinued > SPD-3.1M
 > uncategorized - discontinued > SPD-3.1M
 > uncategorized - discontinued > SPD-3.1M
 > uncategorized - discontinued > SPD-3.1M

Questions and answers

1. Which Russian companies represent the products of PE "ARTON"?

As of February 24, 2022, our company has terminated all ties with the Russian Federation.

Publications

Edition/Site Year Title of the article Open Download
Security systems 1 2010 A look at fire smoke detectors through the lens of test fires. Part 1
Security systems 2 2010 A look at fire smoke detectors through the lens of test fires. Part 2
www.sec.ru 3 2014 Smoke optical-electronic point fire detectors. Basic circuit solutions. Part 1.1. Flowcharts
www.sec.ru 3 2014 Smoke optical-electronic point fire detectors. Basic circuit solutions. Part 4.1 Fire detector output stage
www.sec.ru 3 2014 Smoke optical-electronic point fire detectors. Basic circuit solutions. Part 3. IR Emitters
www.sec.ru 3 2014 Smoke optical-electronic point fire detectors. Basic circuit solutions. Part 2.3. Transistor photo amplifiers
www.sec.ru 3 2014 Smoke optical-electronic point fire detectors. Basic circuit solutions. Part 2.2. Transistor photo amplifiers
www.sec.ru 3 2014 Smoke optical-electronic point fire detectors. Basic circuit solutions. Part 2.1. Transistor photo amplifiers